Skip to content

Commit

Permalink
Update numeric fields to use float
Browse files Browse the repository at this point in the history
The Redfish schema uses the types 'integer' and 'numeric' for field
types. The integer type should be a go int, but numeric types could
contain decimal precision. These fields either need to use float32 or
float64 to handle this.

This updates all redfish objects to use a float type for any that are
defined as numeric in the schema.

Closes: #68

Signed-off-by: Sean McGinnis <[email protected]>
  • Loading branch information
stmcginnis committed Jun 4, 2020
1 parent de6aaee commit 769c294
Show file tree
Hide file tree
Showing 6 changed files with 149 additions and 19 deletions.
146 changes: 137 additions & 9 deletions redfish/chassis.go
Original file line number Diff line number Diff line change
Expand Up @@ -73,6 +73,74 @@ const (
ZoneChassisType ChassisType = "Zone"
)

// EnvironmentalClass is
type EnvironmentalClass string

const (

// A1EnvironmentalClass ASHRAE Environmental Class 'A1'.
A1EnvironmentalClass EnvironmentalClass = "A1"
// A2EnvironmentalClass ASHRAE Environmental Class 'A2'.
A2EnvironmentalClass EnvironmentalClass = "A2"
// A3EnvironmentalClass ASHRAE Environmental Class 'A3'.
A3EnvironmentalClass EnvironmentalClass = "A3"
// A4EnvironmentalClass ASHRAE Environmental Class 'A4'.
A4EnvironmentalClass EnvironmentalClass = "A4"
)

// IntrusionSensor is
type IntrusionSensor string

const (

// NormalIntrusionSensor No abnormal physical security condition is
// detected at this time.
NormalIntrusionSensor IntrusionSensor = "Normal"
// HardwareIntrusionIntrusionSensor A door, lock, or other mechanism
// protecting the internal system hardware from being accessed is
// detected to be in an insecure state.
HardwareIntrusionIntrusionSensor IntrusionSensor = "HardwareIntrusion"
// TamperingDetectedIntrusionSensor Physical tampering of the monitored
// entity is detected.
TamperingDetectedIntrusionSensor IntrusionSensor = "TamperingDetected"
)

// IntrusionSensorReArm is
type IntrusionSensorReArm string

const (

// ManualIntrusionSensorReArm A manual re-arm of this sensor restores it
// to the normal state.
ManualIntrusionSensorReArm IntrusionSensorReArm = "Manual"
// AutomaticIntrusionSensorReArm Because no abnormal physical security
// condition is detected, this sensor is automatically restored to the
// normal state.
AutomaticIntrusionSensorReArm IntrusionSensorReArm = "Automatic"
)

// PhysicalSecurity shall describe the sensor state of the physical
// security.
type PhysicalSecurity struct {

// IntrusionSensor is This property shall represent the state of this
// physical security sensor. Hardware intrusion indicates the internal
// hardware is detected as being accessed in an insecure state.
// Tampering detected indicates the physical tampering of the monitored
// entity is detected.
IntrusionSensor IntrusionSensor
// IntrusionSensorNumber is This property shall contain a numerical
// identifier for this physical security sensor that is unique within
// this resource.
IntrusionSensorNumber int
// IntrusionSensorReArm is This property shall represent the method that
// restores this physical security sensor to the normal state. Manual
// indicates manual re-arm is needed. Automatic indicates the state is
// restored automatically because no abnormal physical security
// conditions are detected.
IntrusionSensorReArm IntrusionSensorReArm
}

// Chassis represents the physical components of a system. This
// resource represents the sheet-metal confined spaces and logical zones such
// as racks, enclosures, chassis and all other containers. Subsystems (like sensors)
Expand All @@ -81,15 +149,75 @@ const (
// indirectly through this resource.
type Chassis struct {
common.Entity
ChassisType ChassisType `json:"ChassisType"`
Manufacturer string `json:"Manufacturer"`
Model string `json:"Model"`
SKU string `json:"SKU"`
SerialNumber string `json:"SerialNumber"`
Version string `json:"Version"`
PartNumber string `json:"PartNumber"`
AssetTag string `json:"AssetTag"`
Status common.Status `json:"Status"`

// ODataContext is the odata context.
ODataContext string `json:"@odata.context"`
// ODataEtag is the odata etag.
ODataEtag string `json:"@odata.etag"`
// ODataType is the odata type.
ODataType string `json:"@odata.type"`
// AssetTag shall contain an identifying string that
// tracks the chassis for inventory purposes.
AssetTag string
// ChassisType shall indicate the physical form factor
// for the type of chassis.
ChassisType ChassisType
// DepthMm shall represent the depth (length) of the
// chassis, in millimeters, as specified by the manufacturer.
DepthMm float64
// Description provides a description of this resource.
Description string
// EnvironmentalClass shall contain the ASHRAE
// Environmental Class for this chassis, as defined by ASHRAE Thermal
// Guidelines for Data Processing Environments. These classes define
// respective environmental limits that include temperature, relative
// humidity, dew point, and maximum allowable elevation.
EnvironmentalClass EnvironmentalClass
// HeightMm shall represent the height of the chassis,
// in millimeters, as specified by the manufacturer.
HeightMm float64
// IndicatorLED shall contain the indicator light state
// for the indicator light associated with this system.
IndicatorLED common.IndicatorLED
// Location shall contain location information of the
// associated chassis.
Location common.Location
// Manufacturer shall contain the name of the
// organization responsible for producing the chassis. This organization
// might be the entity from whom the chassis is purchased, but this is
// not necessarily true.
Manufacturer string
// Model shall contain the name by which the
// manufacturer generally refers to the chassis.
Model string
// PartNumber shall contain a part number assigned by
// the organization that is responsible for producing or manufacturing
// the chassis.
PartNumber string
// PhysicalSecurity shall contain the sensor state of
// the physical security.
PhysicalSecurity PhysicalSecurity
// PowerState shall contain the power state of the
// chassis.
PowerState PowerState
// SKU shall contain the stock-keeping unit number for
// this chassis.
SKU string
// SerialNumber shall contain a manufacturer-allocated
// number that identifies the chassis.
SerialNumber string
// Status shall contain any status or health properties
// of the resource.
Status common.Status
// UUID shall contain the universal unique identifier
// number for this chassis.
UUID string
// WeightKg shall represent the published mass, commonly
// referred to as weight, of the chassis, in kilograms.
WeightKg float64
// WidthMm shall represent the width of the chassis, in
// millimeters, as specified by the manufacturer.
WidthMm float64
thermal string
power string
networkAdapters string
Expand Down
8 changes: 4 additions & 4 deletions redfish/drive.go
Original file line number Diff line number Diff line change
Expand Up @@ -136,7 +136,7 @@ type Drive struct {
BlockSizeBytes int
// CapableSpeedGbs shall contain fastest capable bus speed of the associated
// drive.
CapableSpeedGbs int
CapableSpeedGbs float32
// CapacityBytes shall contain the raw size in bytes of the associated drive.
CapacityBytes int64
// Description provides a description of this resource.
Expand Down Expand Up @@ -179,7 +179,7 @@ type Drive struct {
Multipath bool
// NegotiatedSpeedGbs shall contain current bus speed of the associated
// drive.
NegotiatedSpeedGbs int
NegotiatedSpeedGbs float32
// Operations shall contain a list of all operations currently running on
// the Drive.
Operations []common.Operations
Expand All @@ -191,15 +191,15 @@ type Drive struct {
PhysicalLocation common.Location
// PredictedMediaLifeLeftPercent shall contain an indicator of the
// percentage of life remaining in the Drive's media.
PredictedMediaLifeLeftPercent int
PredictedMediaLifeLeftPercent float32
// Protocol shall contain the protocol the associated drive is using to
// communicate to the storage controller for this system.
Protocol common.Protocol
// Revision shall contain the revision as defined by the manufacturer for
// the associated drive.
Revision string
// RotationSpeedRPM shall contain rotation speed of the associated drive.
RotationSpeedRPM int
RotationSpeedRPM float32
// SKU shall be the stock-keeping unit number for this drive.
SKU string
// SerialNumber is used to identify the drive.
Expand Down
2 changes: 1 addition & 1 deletion redfish/drive_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -115,7 +115,7 @@ func TestDrive(t *testing.T) {
}

if result.CapableSpeedGbs != 40 {
t.Errorf("Incorrect capable speed: %d", result.CapableSpeedGbs)
t.Errorf("Incorrect capable speed: %f", result.CapableSpeedGbs)
}

if result.CapacityBytes != 1099511627776 {
Expand Down
6 changes: 3 additions & 3 deletions redfish/memorymetrics.go
Original file line number Diff line number Diff line change
Expand Up @@ -56,9 +56,9 @@ type HealthData struct {
PerformanceDegraded bool
// PredictedMediaLifeLeftPercent shall contain an indicator
// of the percentage of life remaining in the media.
PredictedMediaLifeLeftPercent int
PredictedMediaLifeLeftPercent float32
// RemainingSpareBlockPercentage shall be the remaining spare blocks in percentage.
RemainingSpareBlockPercentage int
RemainingSpareBlockPercentage float32
}

// LifeTime shall describe the metrics of the memory since manufacturing.
Expand All @@ -84,7 +84,7 @@ type MemoryMetrics struct {
// percentage. When this resource is subordinate to the MemorySummary
// object, this property shall be the memory bandwidth utilization over all
// memory as a percentage.
BandwidthPercent int
BandwidthPercent float32
// BlockSizeBytes shall be the block size in bytes of all structure elements.
BlockSizeBytes int
// CurrentPeriod shall contain properties which describe the CurrentPeriod
Expand Down
2 changes: 1 addition & 1 deletion redfish/power.go
Original file line number Diff line number Diff line change
Expand Up @@ -276,7 +276,7 @@ type PowerSupply struct {
assembly string
// EfficiencyPercent shall contain the value of the measured power
// efficiency, as a percentage, of the associated power supply.
EfficiencyPercent int
EfficiencyPercent float32
// FirmwareVersion shall contain the firmware version as
// defined by the manufacturer for the associated power supply.
FirmwareVersion string
Expand Down
4 changes: 3 additions & 1 deletion tools/generate_from_schema.py
Original file line number Diff line number Diff line change
Expand Up @@ -107,8 +107,10 @@ def _get_type(name, obj):
for kind in tipe:
if kind == 'null':
continue
if kind == 'integer' or kind == 'number':
if kind == 'integer':
result = 'int'
elif kind == 'number':
result = 'float64'
elif kind == 'boolean':
result = 'bool'
else:
Expand Down

0 comments on commit 769c294