Skip to content

Releases: emsesp/EMS-ESP32

Development Build v3.7.2-dev.2

02 Dec 21:23
473cf7c
Compare
Choose a tag to compare
Pre-release

Commits

v3.7.1

30 Nov 20:51
Compare
Choose a tag to compare

[3.7.1] 29 November 2024

Added

  • include HA "unit_of_meas", "stat_cla" and "dev_cla" attributes for Number sensors #2149
  • Bosch CS6800i AW - Silent Mode + Electrical Power Reduction (HP) #2147
  • /api/system/showeralert and /api/system/showertimer #2182
  • MX400 #2198
  • SM200 values #2212

Fixed

  • Modbus integration in 3.7.0 missing offset #2148
  • fix changing TZ in NTPsettings without clearing enable+server, added DST support #2142
  • Support MQTT Discovery (AD) with Domoticz #2177
  • wwExtra (dhw extra) changed from temperature reading to number
  • auxheaterstatus #2192
  • lastCode character check #2189
  • reading too many telegram parts
  • heatpump cost UOMs #2188
  • analog dac output and inputs on dac pins #2201
  • api memory leak #2216
  • modbus multiple mixers #2229
  • Last Will (LWT) not set on MQTT Connect #2247

Changed

  • name of wwstarts2 #2217

Commits

Read more

v3.7.0

27 Oct 10:53
Compare
Choose a tag to compare

[3.7.0] October 27 2024

IMPORTANT! BREAKING CHANGES with 3.6.5

  • "ww" and "wwc" has been renamed to "dhw". It is nested JSON object in both the MQTT and API outputs. The old prefix has also been removed from MQTT topics (#1634). This will impact historical data in home automation systems like Home Assistant and IOBroker. To preserve the current value of dhw energy (was previously nrgww) refer to this issue #1938.
  • dhw entities from the MM100/SM100 have been moved under a new Device called 'water'.
  • The automatically generated temperature sensor ID has replaced dashes (-) with underscores (_) to be compatible with Home Assistant.
  • api/system/info has it's JSON key names changed to camelCase syntax.

For more details go to www.emsesp.org

Added

  • some more entities for dhw with SM100 module
  • thermostat second dhw circuit #1634
  • remote thermostat emulation for RC100H, RC200 and FB10 #1287, #1602, #1551
  • heatpump dhw stop temperatures #1624
  • reset history #1695
  • heatpump entities fan and shutdown #1690
  • mqtt HA-mode 3 for v3.6 compatible HA entities, set on update v3.6->v3.7
  • HP input states #1723
  • holiday settings for rego 3000 #1735
  • Added scripts for OTA (scripts/upload.py and upload_cli.py) #1738
  • timeout for remote thermostat emulation #1680, #1774
  • CR120 thermostat as own model() #1779
  • modules - external linkable module library #1778
  • scheduler onChange and Conditions #1806
  • make remote control timeout editable #1774
  • added extra pump characteristics (mode and pressure for EMS+) by @SLTKA #1802
  • allow device name to be customized #1174
  • Modbus support by @mheyse #1744
  • System Message command #1854
  • scheduler can use web get/post for values and commands #1806
  • RT800 remote emulation #1867
  • RC310 cooling parameters #1857
  • command api/device/entities #1897
  • switchprogmode #1903
  • autodetect and download firmware upgrades via the WebUI
  • command 'show log' that lists out the current weblog buffer, showing last messages.
  • default web log buffer to 25 lines for ESP32s with no PSRAM
  • try and determine correct board profile if none is set during boot
  • auto Scroll in WebLog UI - reduced delay so incoming logs are faster
  • uploading custom support info, shown to Guest users in Help page #2054
  • feature: Dashboard showing all data (favorites, sensors, custom) #1958
  • entity for low-temperature boilers pump start temp (pumpOnTemp) #2088 #2088
  • internal ESP32 temperature sensor on the S3 #2077
  • MQTT status topic (used in connect and last will) set to Retain #2086
  • Czech language 2096
  • Developer Mode and send EMS Read Commands from WebUI #2116
  • Scheduler functions #2115
  • Set device custom name from telegram 0x01 #2073

Fixed

  • remote thermostat emulation for RC200 on Rego2000/3000 thermostats #1691
  • log shows data for F7/F9 requests
  • Detection of LittleFS for factory setting wasn't working
  • Check for bad GPIOs with Ethernet before the ethernet is initialized
  • Show values with factor 50 on webUI #2064
  • Rendering of values between -1 and 0
  • Value for 32bit times not-set #2109

Changed

  • use flag for BC400 compatible thermostats, manage different mode settings
  • use factory partition for 16M flash
  • store digital out states to nvs
  • Refresh UI - moving settings to one location #1665
  • rename DeviceValueTypes, add UINT32 for custom entities
  • dynamic register dhw circuits for thermostat
  • removed OTA feature #1738
  • added shower min duration #1801
  • Include TXT file along with the generated CSV for Device Data export/download
  • thermostat/remotetemp as command #1835
  • temperaturesensor id notation with underscore #1794
  • Change key-names in JSON to be compliant and consistent #1860
  • Updates to webUI #1920
  • Correct firmware naming #1933 #1933
  • Don't start Serial console if not connected to a Serial port. Will initiate manually after a CTRL-C/CTRL-S
  • WebLog UI matches color schema of the terminal console correctly
  • Updated Web libraries, ArduinoJson
  • Help page doesn't show detailed tech info if the user is not 'admin' role #2054
  • removed system command allvalues and moved to an action called export
  • Show ems-esp internal devices in device list of system/info
  • Scheduler and mqtt run async on systems with psram
  • Show IPv6 address type (local/global/ula) in log

v3.6.5

23 Mar 17:03
Compare
Choose a tag to compare

[3.6.5] March 23 2024

IMPORTANT! BREAKING CHANGES

  • The Wifi Tx Power setting in Network Settings will be reset to Auto

Added

  • thermostat boost mode and boost time #1446
  • heatpump energy meters #1463
  • heatpump max power #1475
  • checkbox for MQTT-TLS enable #1474
  • added SK (Slovak) language. Thanks @misa1515
  • CPU info #1497
  • Show network hostname in Web UI under Network Status
  • Improved HA Discovery so each section (EMS device, Scheduler, Analog, Temperature, Custom, Shower) have their own section
  • boiler Bosch C1200W, id 12, #1536
  • mixer MM100 telegram 0x2CC #1554
  • boiler hpSetDiffPressure #1563
  • custom variables #1423
  • weather compensation #1642
  • env and partitions for DevKitC-1-N32R8 #1635
  • command restart partitionname and button long press to start with other partition #1657
  • command set service <mqtt|ota|ntp|ap> <enable|disable> #1663

Fixed

  • exhaust temperature for some boilers
  • add back boil2hyst #1477
  • subscribed MQTT topics not detecting changes by EMS-ESP #1494
  • changed HA name and grouping to be consistent #1528
  • MQTT autodiscovery in Domoticz not working #1360
  • dhw comfort for new ems+, #1495
  • added writeable icon to Web's Custom Entity page for each entity shown in the table
  • Wifi Tx Power not adjusted #1614
  • MQTT discovery of custom entity doesn't consider type of data #1587
  • WiFi TxPower wasn't correctly used. Added an 'Auto' setting, which is the default.
  • dns w/wo IPv6 #1644

Changed

  • HA don't set entity_category to Diagnostic/Configuration for EMS entities #1459
  • upgraded ArduinoJson to 7.0.0 #1538 and then 7.0.2
  • small changes to the API for analog and temperature sensors
  • Length of mqtt Broker address #1619
  • C++ optimizations - see #1615
  • Send MQTT heartbeat immediately after connection #1628
  • 16MB partitions with second nvs, larger FS, Coredump, optional factory partition
  • stop fetching empty telegrams after 5 min

v3.6.4

26 Nov 19:18
Compare
Choose a tag to compare

[3.6.4] November 24 2023

IMPORTANT! BREAKING CHANGES

Writeable Text entities have moved from type sensor to text in Home Assistant to make them also editable within an HA dashboard. Examples are datetime, holidays, switchtime, vacations, maintenancedate... You will need to manually remove any old discovery topics from your MQTT broker using an application like MQTT Explorer.

Added

  • humidity for ventilation devices
  • telegrams for RC100H, hc2, etc. (seen on discord, not tested)
  • names for BC400, GB192i.2, read temperatures for low loss header and heatblock #1317
  • option for forceheatingoff #1262
  • remote thermostat emulation RC100H for RC3xx #1278
  • shower_data MQTT payload contains the timestamp #1329
  • HA discovery for writeable text entities #1337
  • autodetect board_profile, store in nvs, add telnet command option, add E32V2
  • heat pump high res energy counters #1348, #1349. #1350
  • optional bssid in network settings
  • extension module EM100 #1315
  • digital_out with new options for polarity and startup state
  • added 'system allvalues' command that dumps all the EMS device values, plus sensors and any custom entities

Fixed

  • remove command remoteseltemp, thermostat accept it only from remote thermostat
  • shower_data MQTT payload contains the timestamp #1329
  • fixed helper text in Web Device Entity dialog box for numerical ranges
  • MQTT base with paths not working in HA #1393
  • set/read thermostat mode for RC100-RC300, #1440 #1442

Changed

  • update to platform 6.4.0, arduino 2.0.14 / idf 4.4.6
  • small changes for arduino 3.0.0 / idf 5.1 compatibility (not backward compatible to platform 6.3.2 and before)
  • AP start after 10 sec, stay until station/eth connected
  • tested wifi-all-channel-scan (3.6.3-dev4 a-e), removed again because of connect issues
  • mqtt disconnect stops queue

Chores

Commits

Read more

v3.6.2

01 Oct 15:51
Compare
Choose a tag to compare

Commits

v3.6.1

09 Sep 12:19
Compare
Choose a tag to compare

[3.6.1]

IMPORTANT! BREAKING CHANGES

  • shower_data MQTT topic shows duration is seconds (was previously a full english sentence)

Added

  • show WiFi rssi in Network Status Page, show quality as color

Fixed

  • Issue in espMqttClient causing a memory leak when MQTT broker is disconnected due to network unavailability #1264
  • Using MQTT enum values correctly formatted in MQTT Discovery #1280

Changed

  • mqtt free mem check set to 60 kb
  • small cosmetic changes to Searching in Customization web page
  • updated to [email protected]

Commits

v3.6.0

13 Aug 13:06
86e2951
Compare
Choose a tag to compare

[3.6.0] August 13 2023

IMPORTANT! BREAKING CHANGES

There are breaking changes between 3.5.x and earlier versions of 3.6.0. Please read carefully before applying the update.

  • The sensors have been renamed. dallassensor is now temperaturesensor in the MQTT topic and named ts in the Customizations file. Likewise analogs is now analogsensor in MQTT and called as in the Customizations file. If you have previous customizations you will need to manually update by downloading, changing the JSON file and uploading. It's also recommended cleaning up any old MQTT topics from your broker using an application like MQTTExplorer.

Added

  • Workaround for better Domoticz MQTT intergration? #904
  • Show MAC address without connecting to network enhancement #933
  • Warn user in WebUI of unsaved changes #911
  • Detect old Tado thermostat, device-id 0x19, no entities
  • Some more HM200 entities #500
  • Added Scheduler #701
  • Added Custom Entities read/write from EMS bus
  • Build S3 binary with github actions
  • Greenstar HIU #1158
  • AM200 code 10 #1161
  • Ventilation device (Logavent HRV176) #1172
  • Turn ETH off on wifi connect #1167
  • Support for multiple EMS-ESPs with HA #1196
  • Italian translation #1199
  • Turkish language support #1076
  • Buderus GB182 - HC1 mode change not work bug #1193
  • Minimal flow temperature enhancement #1192
  • Roomtemperature Switching Difference enhancement #1191
  • Dew Point Temperature Difference enhancement #1190
  • Control of heating circuit mode enhancement #1187
  • Warn user in WebUI of unsaved changes enhancement #911
  • Create safebuild app to fit into factory partition to give ESP32 more flash memory enhancement #608
  • Support ESP32 S2, C3 mini and S3 #605
  • Support Buderus AM200 #1161
  • Custom telegram handler #1155
  • Added support for TLS in MQTT (ESP32-S3 only) #1178
  • Boardprofile BBQKees Gateway S3
  • Custom entity type RAW #1212
  • API command response #1212

Fixed

  • HA-discovery for analog sensor commands #1035
  • Enum order of RC3x nofrost mode
  • Heartbeat interval
  • Exhaust temperature always zero on GB125/MC110/RC310 bug #1147
  • thermostat modetype is not changing when mode changes (e.g. to night) bugSomething isn't working #1098
  • NTP: cant apply changed timezone #1182
  • Missing Status of VS1 for Buderus SM200 enhancement #1034
  • Allowed gpios for S3

Changed

  • Optional upgrade to platform-espressif32 6.3.0 (after 5.3.0) #862
  • Use byte 3 for detection RC30 active heatingcircuit #786
  • Write repeated selflowtemp if tx-queue is empty without verify #954
  • HA discovery recreate after disconnect by device #1067
  • File upload: check flash size (overflow) instead of filesize
  • Improved HA Discovery so previous configs no longer need to be removed when starting #1077 (thanks @pswid)
  • Enlarge UART-Stack to 2,5k
  • Retry timeout for Mqtt-QOS1/2 10seconds
  • Optimize WebUI rendering when using Dialog Boxes #1116
  • Optimize Web libraries to reduce bundle size (3.6.x) #1112
  • Use espMqttClient with integrated queue #1178
  • Move Sensors from Web dashboard to it's own tab enhancement #1170
  • Optimize WebUI dashboard data #1169
  • Replace React core library with Preact to save on memory footprint
  • Response to system/send raw reads gives combined data for telegrams with more parts

Commits

Read more

v3.5.1

11 Mar 15:11
Compare
Choose a tag to compare

[3.5.1] March 11 2023

Added

  • Detect old Tado thermostat, device-id 0x19, no entities
  • Some more HM200 entities #500
  • Add entity to force heating off (for systems without thermostat) #951

Fixed

  • HA-discovery for analog sensor commands #1035

Changed

  • Use byte 0 for detection RC30 active heatingcircuit #786
  • Write repeated selflowtemp if tx-queue is empty without verify #954
  • HA discovery recreate after disconnect by device #1067
  • File upload: check flash size (overflow) instead of filesize

v3.5.0

06 Feb 21:04
Compare
Choose a tag to compare

[3.5.0]

IMPORTANT! BREAKING CHANGES

  • When upgrading to v3.5 for the first time from v3.4 on a BBQKees Gateway board you will need to use the EMS-EPS Flasher to correctly re-partition the flash. Make sure you backup the settings and customizations from the WebUI (System->Upload/Download) and restore after the upgrade.
  • Support for multiple EMS-ESPs [#759] has been added as an optional setting for MQTT. When enabled, which is now the default, all MQTT Discovery Entity IDs will include the MQTT base name and the shortname of the EMS-ESP device entity. For example what was previously sensor.boiler_actual_boiler_temperature will now become sensor.ems_esp_boiler_boiltemp. If you still want to use the old format and retain the history and script compatibility in Home Assistant then set this back to the old format.

Added

  • Translations in Web UI and all device entity names (DE, NL, SV, PL, NO, FR) #22
  • Add support for Lolin C3 mini #620
  • Add support for ESP32-S2 #667
  • Add devices: Greenstar 30Ri boiler, Junkers FW500 thermostat, Buderus BC30 controller
  • Add program memory info
  • Add mqtt queue and connection infos
  • Adapt min/max if ems-value is not in this range
  • Add heat pump settings for inputs and limits #600
  • Add hybrid heatpump #500
  • Add translated tags
  • Add min/max to customization table #686
  • Add MD5 check #637
  • Add more bus-ids #673
  • Use HA connectivity device class for Status, added boot time #751
  • Add commands for analog sensors outputs
  • Support for multiple EMS-ESPs with MQTT and HA [#759]
  • Settings for heatpump silent mode and additional heater [#802] [#803]
  • Zone module MZ100 #826
  • Default MQTT hostname is blank #829
  • wwCurFlow for ems+ devices #829
  • Add Rego 3000, TR120RF thermostats #917
  • Add config for ESP32-S3
  • Add heatpump silent mode and other entities #896
  • Allow reboot to other partition (factory or asymetric OTA)
  • Blacklist entities to remove from memory #891
  • Add boiler pump operating mode #944

Fixed

  • Factory Reset not working #628
  • Valid 4 byte values #820
  • Commands for multiple thermostats #826
  • API queries for multiple devices #865
  • Console crash when using call with command hcx only. #841
  • heatingPump2Mod was wrong, changed to absBurnPow [#908
  • Rounding of web input values
  • Analog sensor with single gpio number #915
  • HA dallas and analog configs: remove/rebuild on change #888
  • Modes and set seltemp for RC30 and RC20 #932

Changed

  • Discovery in HomeAssistant don't work with custom base topic. #596 Base topic containing / are changed to _
  • RF room temperature sensor are shown as thermostat
  • Render mqtt float json values with trailing zero
  • Removed flash strings, to increase available heap memory
  • Reload page after restart button is pressed
  • Analog/dallas values command as list like ems-devices
  • Analog/dallas HA-entities based on id
  • MQTT Base is a mandatory field. Removed MQTT topic length from settings
  • HA duration class for time entities [#822
  • AM200 alternative heatsource as class heatsource [#857

Commits

Read more