Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

fix(plc4py/umas): Start cleaning up the umas protocol #1749

Draft
wants to merge 2 commits into
base: develop
Choose a base branch
from
Draft
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
53 changes: 41 additions & 12 deletions protocols/umas/src/main/resources/protocols/umas/umas.mspec
Original file line number Diff line number Diff line change
Expand Up @@ -17,29 +17,29 @@
* under the License.
*/

// https://Umas.org/docs/Umas_Application_Protocol_V1_1b.pdf
// https://modbus.org/docs/Modbus_Application_Protocol_V1_1b.pdf

// Remark: The different fields are encoded in Big-endian.
// Remark: The different fields are encoded in Big-endian for Modbus. UMAS uses Little-Endian

[type UmasConstants
[const uint 16 UmasTcpDefaultPort 502]
[type ModbusConstants
[const uint 16 ModbusTcpDefaultPort 502]
]

[discriminatedType ModbusTcpADU byteOrder='BIG_ENDIAN'
// It is used for transaction pairing, the Umas server copies in the response the transaction
// It is used for transaction pairing, the Mobus server copies in the response the transaction
// identifier of the request.
[simple uint 16 transactionIdentifier]

// It is used for intra-system multiplexing. The Umas protocol is identified by the value 0.
// It is used for intra-system multiplexing. The Modbus protocol is identified by the value 0.
[const uint 16 protocolIdentifier 0x0000]

// The length field is a byte count of the following fields, including the Unit Identifier and
// data fields.
[implicit uint 16 length 'COUNT(pduArray) + 1']

// This field is used for intra-system routing purpose. It is typically used to communicate to
// a Umas+ or a Umas serial line slave through a gateway between an Ethernet TCP-IP network
// and a Umas serial line. This field is set by the Umas Client in the request and must be
// a Modbus serial line slave through a gateway between an Ethernet TCP-IP network
// and a Umas serial line. This field is set by the Modbus Client in the request and must be
// returned with the same value in the response by the server.
[simple uint 8 unitIdentifier]

Expand All @@ -61,27 +61,40 @@
]

[type UmasPDUItem(uint 8 umasRequestFunctionKey, uint 16 byteLength) byteOrder='LITTLE_ENDIAN'
// Not too sure what this is. It is normally 0x00 or 0xFF
[simple uint 8 pairingKey]
[discriminator uint 8 umasFunctionKey]
[typeSwitch umasFunctionKey, umasRequestFunctionKey
// Opens a connection to the PLC to enable reading and writing. It use one connection from the PLC.
['0x01' UmasInitCommsRequest
[simple uint 8 unknownObject]
[const uint 8 unknownObject 0x00]
]
['0x02' UmasPDUPlcIdentRequest
]
// Requests information about the running project
['0x03' UmasPDUProjectInfoRequest
[simple uint 8 subcode]
]
// Requests information about the PLC, it mainly contains useful information about each memory block
['0x04' UmasPDUPlcStatusRequest
]
// Request to read data from a memory block defined by the Block No. and Offset.
['0x20' UmasPDUReadMemoryBlockRequest
[simple uint 8 range]
[const uint 8 range 0x00]
// The memory block number to be read.
[simple uint 16 blockNumber]
// The offset from the start of the block to read
[simple uint 16 offset]
// Not sure but probably some other offset
[simple uint 16 unknownObject1]
// The number of bytes to read
[simple uint 16 numberOfBytes]
]
// Used to read the values of variables. The variable information must firstly be looked up using a UmasPDUReadUnlocatedVariableNamesRequest
['0x22' UmasPDUReadVariableRequest
// This can be calculated from a UmasPDUPlcStatusResponse by adding blocks 3 and 4.
// It is a unique value for the current project on the PLC. If there are any modifications then this changes.
// It is used to detect a programming change to know when to re-read the tag information.
[simple uint 32 crc]
[simple uint 8 variableCount]
[array VariableReadRequestReference variables count 'variableCount']
Expand All @@ -91,9 +104,13 @@
[simple uint 8 variableCount]
[array VariableWriteRequestReference variables count 'variableCount']
]
['0x26' UmasPDUReadUnlocatedVariableNamesRequest
// Is used to read information from the data dictionary such as tag names, data types, etc...
['0x26' UmasPDUReadDataDictionaryRequest
// I've seen values 0xDD02 and 0xDD03 being used
[simple uint 16 recordType]
// This is an index from the UmasMemoryBlockBasicInfo message
[simple uint 8 index]
// This seems to be a unique number returned from the UmasMemoryBlockBasicInfo
[simple uint 32 hardwareId]
[simple uint 16 blockNo]
[simple uint 16 offset]
Expand All @@ -103,14 +120,18 @@
[array uint 8 block count 'byteLength - 2']
]
['0xFE', '0x01' UmasInitCommsResponse
// The largest UMAS packet size. I don't think it includes the Modbus header
[simple uint 16 maxFrameSize]
// PLC Firmware Version
[simple uint 16 firmwareVersion]
[simple uint 32 notSure]
[simple uint 32 internalCode]
[simple uint 8 hostnameLength]
// PLC Name returned a string
[simple vstring 'hostnameLength*8' hostname]
]
['0xFE', '0x02' UmasPDUPlcIdentResponse
// I don't have a lot of information about these, but can be used to identify the PLC/Firmware/Hardware version if we ever have a need
[simple uint 16 range]
[simple uint 32 ident]
[simple uint 16 model]
Expand All @@ -123,26 +144,34 @@
[simple uint 8 hostnameLength]
[simple vstring 'hostnameLength*8' hostname]
[simple uint 8 numberOfMemoryBanks]
// List of memory blocks within the PLC.
[array PlcMemoryBlockIdent memoryIdents count 'numberOfMemoryBanks']
]
['0xFE', '0x04' UmasPDUPlcStatusResponse
// This has some information, presumably about the current project. We need blocks 3 and 4 to work out the CRC of the project.
// We monitor these to check if the project has changed, if so we re-read the data dictionary
[simple uint 8 notUsed1]
[simple uint 16 notUsed2]
[simple uint 8 numberOfBlocks]
[array uint 32 blocks count 'numberOfBlocks']
]
['0xFE', '0x20' UmasPDUReadMemoryBlockResponse
// Simply reads a section of memory. A UmasMemoryBlock can be returned, I don't have much information on what other blocks mean though.
[simple uint 8 range]
[simple uint 16 numberOfBytes]
[array uint 8 block count 'numberOfBytes']
]
['0xFE', '0x22' UmasPDUReadVariableResponse
// It just returns the variable data which can then be decoded with the DataIO.
[array uint 8 block count 'byteLength - 2']
]
['0xFE', '0x23' UmasPDUWriteVariableResponse
[array uint 8 block count 'byteLength - 2']
]
['0xFE', '0x26' UmasPDUReadUnlocatedVariableResponse
// Reads information from the data dictionary.
// we can read one of UmasPDUReadUnlocatedVariableNamesResponse, UmasPDUReadUmasUDTDefinitionResponse or UmasPDUReadDatatypeNamesResponse
// Which depends on the request that was sent.
['0xFE', '0x26' UmasPDUReadDataDictionaryResponse
[array uint 8 block count 'byteLength - 2']
]
]
Expand Down