============== KS_PowerPallet - firmware for the All Power Labs Power Pallet(TM) PCU. ============== Download the latest version of this source code at: https://github.com/allpowerlabs/KS_PowerPallet === Compatibility === This software is compatible with hardware version 1.09 of the Power Pallet, and will not work properly with previous Power Pallets. This essentially means only Power Pallets with a version 5 reactor. === Building This Software === This version requires avr-gcc-4.3, avr-libc-1.6.2, and Arduino-0023. Later versions of these tools will fail to compile this code. Also, you will need KSlibs and the modified versions of various Arduino libraries from: https://github.com/allpowerlabs/libraries === Change Log === January 20, 2016 - v1.3.3 Maintenance release Added SHUTDOWN to screen during engine shutdown state “GRATE”/FET1 output remapped for governor Run Enable shutdown Testing screen shows remapped Run Enable correctly Testing screen shows that FET3 is used for shutdown (GT) Mapped reduction high to correct alarm Fixed Oil Pressure shutdown alarm persistence bug Added alarm shutdown diagnostics to log (GT) May 27, 2015 - v1.3.2 Maintenance release Bug 9 - Frequency of switching from new "flex" switch may exceed automotive relay life Bug 60 - Allow engine to run with reactor at low temperature for up to 3 minutes. Bug 64 - Update configuration default for ash auger run time to 200 seconds. ECR-000249 - Flex Switch reduce frequency starts + flex paddle shape quest April 28, 2015 - v1.3.1 Maintenance release Bug #1, Frequent auger low current alarms "Auger Low Current" alarms were being generated while the auger motor was off. This was caused by rapid state transitions from the new fuel switch and a bug in the fuel auger control logic. Bug #2, Auger current and fuel switch state not correctly logged Bug #6, Incorrect logging: Alarm Reset by UserNew Auger State: Off Bug #7, Message uses pound symbol: # Deap Sea controller set to: Bug #9, Added a minimum off time to the fuel switch logic to extend the life of the fuel auger relays. The default is 30 seconds, but is adjustable from 1 to 60 seconds. Bug #11, Grate motor power output low. Null EEPROM value wasn't handled correctly, so grate power level was defaulting to 0 instead of 100. Bug #26, Servo start angle setting has no effect. This feature had been disabled a long time ago, probably to speed engine start-up on units where the filter was being bypassed while flaring. Bug #34, Can't determine current software version without power cycling automation Bug #38, Time in seconds greater than 5 chars on main screen wraps to beginning of screen Bug #39, Time displayed on log number screen incorrect This was caused by time being printed as a signed integer and overflowing. Bug #40, Ash auger does not turn off after grate shake correctly Ash auger run time was being being converted to a signed integer when read from EEPROM, and the resulting overflow caused to ash auger to stay on constantly. Bug #52, Fuel auger reverse time should be .5 seconds This was decided as the new default during a meeting with the reactor team. The intent was to reduce material packing behind the auger. Bug #53, Remove unused settings from the configuration menu The following settings were removed from the configuration menu: engine_type - We are currently only supporting PP20 relay_board - We are only supporting units with a relay board pratio_max- Unused display_per - This previously set the rate of display flashing pfilter_alarm - Unused lambda_rich - Unused pratio_high_boundary - Unused grate.revtime - Unused grate.duty - Unused Bug #54, Update configuration default for restriction temperature shutdown Restriction low temperature shutdown default was changed from 650C to 675C. Bug #55, Reduce default grate shake time to 2 seconds This was decided as the new default during a meeting with the reactor team. The intent was to reduce lofting of fines during a grate shake. Bug #56, Update configuration default for ash auger run time to 200 seconds. This was decided as the new default during a meeting with the reactor team. The intent was to reduce wear on the ash auger mechanism. Bug #57, Auger starts in reverse mode when powered up Testing has shown this behavior, which is intentional, to be a non-issue. One modification has been made: the initial reverse pulse before going forward will get its time setting from aug_rev_time, which sets the length of time the auger goes backwards when an obstruction is encountered. Bug #58, Message log time stamp format is confusing Log time is now in seconds with no trailing decimals. Bug #60, ALARM_LOW_TRED and ALARM_TRED_LOW now each have a delay before activating. ALARM_LOW_TRED will not be raised until 120 seconds after the engine has gone into the ON state. ALARM_TRED_LOW will not be raised until the engine has been on for 180 seconds and coincides with an engine shutdown. ECR-000331, Excessive wear rates of gears, auger, scrolls, and motor See bugs #40 and #56 ECR-000354, Engine starting on producer gas is slow See bug #26 SCR-000007, Remove high Pratio alarm SCR-000010, Rename Tred to Trst SCR-000012, Remove flashing temp status SCR-000016, Auger off too long alarm goes off when auger "off". SCR-000020, Auger low current triggered when auger is off See bug #1 SCR-000022, Add external fuel mode Support for external fuels has been added by refactoring the engine control logic to use oil pressure as an indication of a running engine instead of reactor vacuum. July 21, 2014 - v1.3.0 release * Added ash auger system. * Re-wrote grate shaker code for H-bridge drive. * Renamed Ttred and Tbred to Trst and Tred, respectively. * Removed ignition on PCU start, and lean-out on shutdown, when in grid-tie mode. * Various user interface changes * Innumerable under-the-hood improvements. * Added this lovely README file!
About
KS_PowerPallet is the current sketch used to run the All Power Labs Power Pallet. It was introduced with the release of the new relay board.
Resources
Stars
Watchers
Forks
Packages 0
No packages published