Mitsubishi Ecodan Air Source Heat Pumps CN105 Protocol to MQTT for Home Assistant

Notifications You must be signed in to change notification settings

F1p/Mitsubishi-CN105-Protocol-Decode

 
 

Repository files navigation

Mitsubishi Ecodan Bridge CN105

This software between the Mitsubishi Ecodan FTC controller and a MQTT Broker allows data to be read and commands to be sent.

Hardware

Supported Hardware is ESP8266 ebay sold hardware: https://www.ebay.co.uk/itm/325967595655

M5Stack Atom S3 Lite

  1. Download the files from the /build folder.

  2. Download esptool.exe from Espressif.

  3. Place all the files in the same folder, press and hold the side button of the M5Stack, locate the COM port your M5Stack is on

  4. Open CMD prompt in the folder with the files saved and run:

    esptool.exe --chip esp32s3 --port "COM12" --baud 921600  --before default_reset --after hard_reset write_flash -e -z --flash_mode dio --flash_freq 80m --flash_size 4MB 0x0 "ECODAN_Bridge_v5.2.0.bootloader.bin" 0x8000 "ECODAN_Bridge_v5.2.0.partitions.bin" 0xe000 "boot_app0.bin" 0x10000 "ECODAN_Bridge_v5.2.0.bin"
    
  5. The Pins on the M5Stack are: 1 = Tx, 2 = Rx

Wemos D1 Mini

  1. Download the files from the /build folder.

  2. Download upload.py from Github

  3. Place all the files in the same folder, locate the COM port your Wemos D1 Mini is on

  4. Open CMD prompt in the folder with the files saved and run:

    python upload.py --chip esp8266 --port "COM4" --baud "115200" "" erase_flash --before default_reset --after hard_reset write_flash 0x0 "ECODAN_Bridge_v5.2.1_WemosD1.bin"
    
  5. The Pins on the Wemos D1 Mini are: D0 = Tx, D5 = Rx

Mitsubishi CN105 Protocol Decode

For Ecodan ASHP Units this is the protocol decode information https://gitter.im/Mitsubishi-CN105-Protocol-Decode/community

Physical

Serial, 2400, 8, E, 1

Command Format

Header Payload Checksum
5 Bytes 16 Bytes 1 Byte

Header

Sync Byte Packet Type Uknown Unknown Payload Size
0xfc Type 0x02 0x7a Length

Sync Byte

0xfc

Packet Types

Value Packet Type Direction
0x41 Set Request To Heat Pump
0x61 Set Response From Heat Pump
0x42 Get Request To Heat Pump
0x62 Get Response From Heat Pump
0x5A Connect Request To Heat Pump
0x5B Get Request To Heat Pump
0x7A Connect Response From Heat Pump
0x7B Get Response From Heat Pump
0x5B Extended Connect Request To Heat Pump
0x7B Extended Connect Response To Heat Pump

Length

Payload Size (Bytes)

Payload

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Command x x x x x x x x x x x x x x x CHK

Checksum

Checksum = 0xfc - Sum ( PacketBytes[0..20]) ;

Set Request - Packet Type 0x41

Available Commands

Active commands so far identified.

Command Brief Description
0x32 Update Settings
0x34 Hot Water, Holiday and Prohibits
0x35 Thermostat Setpoints

0x32 - Set Options

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x32 Flags Flags P Unk DHW HC1 HC2 DHWSP DHWSP Z1SP Z1SP Z2SP Z2SP MRC MRC CHK
  • Flags (2 Bytes) : Flags to Indicate which fields are active
    • 0x01 0x00 : Set System Power
    • 0x02 0x00 : Unknown (Byte 4) - Operation Mode?
    • 0x04 0x00 : Set Hot Water Mode
    • 0x08 0x00 : Set Heating Control Mode Zone 1
    • 0x10 0x00 : Set Heating Control Mode Zone 2
    • 0x20 0x00 : Set Hotwater Setpoint
    • 0x40 0x00 : Not Required (uint16)
    • 0x80 0x00 : Set Zone 1 Setpoints
    • 0x00 0x01 : Not Required (uint16)
    • 0x00 0x02 : Set Zone 2 Setpoints
    • 0x00 0x04 : Not Required (uint16)
    • 0x00 0x08 : MRC Prohibit
    • 0x00 0x10 : Not Required (uint16)
  • P : System Power
    • 0x00 : Standby
    • 0x01 : Power On
  • DHW : Hot Water Mode
    • 0x00 : Normal
    • 0x01 : Eco
  • HC1 / HC2 : Heating Control Mode Zone 1 / 2
    • 0 : Heating Temperature Mode
    • 1 : Heating Flow Control Mode
    • 2 : Heating Compensation Curve Mode
    • 3 : Cooling Temperature Mode
    • 4 : Cooling Flow Control Mode
    • 5 : Dry Up
  • DHWSP : Hot Water Setpoint (Temperature * 100)
  • Z1SP : Zone 1 Setpoint (* 100)
  • Z2SP : Zone 2 Setpoint (* 100)
  • MRC Prohibit : (Read 0x26 Byte 14) - MRC Prohibit command must NOT be written to Shizuoka designed models
    • 0 : Disable Prohibits
    • 8 : Function Set Prohibit
    • 32 : Setting Temperature Prohibit
    • 64 : Running Mode Prohibit
    • 128 : System On/Off Prohibit

0x34 - Hot Water and Holiday Mode

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x34 Flags Flags DHW HOL IDHW Z1HI Z1CI Z2HI CZ2I SCM Unk1 Unk2 Unk3 Unk4 Unk5 CHK
  • Flags (2 Bytes) : Flags to Indicate which fields are active
    • 0x01 0x00 : Hot Water Force (Boost)
    • 0x02 0x00 : Holiday Mode
    • 0x04 0x00 : DHW Inhibit (Only When in "Server Control Mode")
    • 0x08 0x00 : Heating Z1 Inhibit (Only When in "Server Control Mode")
    • 0x10 0x00 : Cooling Z1 Inhibit (Only When in "Server Control Mode")
    • 0x20 0x00 : Heating Z2 Inhibit (Only When in "Server Control Mode")
    • 0x40 0x00 : Cooling Z2 Inhibit (Only When in "Server Control Mode")
    • 0x80 0x00 : Server Control Mode
    • 0x00 0x01 : Unused 1 (Byte 11)
    • 0x00 0x02 : Unused 2 (Byte 12)
    • 0x00 0x04 : Unused 3 (Byte 13)
    • 0x00 0x08 : Unused 4 (Byte 14)
    • 0x00 0x10 : Unused 5 (Byte 15)
  • DHW : On (1) / Off (0)
  • HOL : On (1) / Off (0)
  • SCM : Server Control Mode On (1) / Off (0)
  • IDHW : Inhibit DHW On (1) / Off (0)
  • Unk1 : Unused (Sets 0x28 Byte 11)
  • Unk2 : Unused (Sets 0x28 Byte 12 - suspected)
  • Unk3 : Unused (Sets 0x28 Byte 13 - suspected)
  • Unk4 : Unused (Sets 0x28 Byte 14 - suspected)
  • Unk5 : Unused (Sets 0x28 Byte 15 - suspected)

0x35 - Set Thermostat Setpoints

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x35 Flags Flags CH Z1SP Z1SP Z2SP Z2SP CHK
  • Flags (2 Bytes) : Flags to Indicate which fields are active
    • 0x01 0x00 : Cooling/Heating
    • 0x02 0x00 : Zone 1 Setpoint
    • 0x04 0x00 : Not Required (uint16)
    • 0x08 0x00 : Zone 2 Setpoint
    • 0x10 0x00 : Not Required (uint16)
    • 0x20 0x00 : Unused (Byte 8)
    • 0x40 0x00 : Unused (Byte 9)
    • 0x80 0x00 : Unused (Byte 10)
    • 0x00 0x01 : Unused (Byte 11)
    • 0x00 0x02 : Unused (Byte 12)
    • 0x00 0x04 : Unused (Byte 13)
    • 0x00 0x08 : Unused (Byte 14)
    • 0x00 0x10 : Unused (Byte 15)
  • CH : Cooling (1) /Heating (0)
  • Z1SP : Zone 1 Setpoint (* 100)
  • Z2SP : Zone 2 Setpoint (* 100)

0xC9 - FTC Information

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0xC9 0x5F
  • 0x5F: Request

Get Request - Packet Type 0x42

Available Commands

Active commands so far identified, 0x00 to 0xff. Commands not listed appear to generate no resaponse. Some command listed have empty, payload 0x00, response.

Command Brief Description
0x01 Time & Date
0x02 Defrost
0x03 Refrigerant and Zone Running Information
0x04 Compressor Frequency
0x05 Hot Water Boot Flag
0x06 Unknown - Empty Response
0x07 Output Power
0x08 Unknown - Empty Response
0x09 Zone 1 & 2 Temperatures and Setpoints, Hot Water Setpoint
0x0b Zone 1 & 2 and Outside
0x0c Water Flow Temperatures
0x0d Boiler Flow Temperatures
0x0e Thermistors 2
0x0f Thermistors 3 (FTC6+ Only)
0x10 External sources
0x11 Unknown
0x13 Run Hours
0x14 Primary Flow Rate
0x15 Unknown Flags
0x16 Running Pumps
0x17 Unknown - Empty Response
0x18 Unknown - Empty Response
0x19 Unknown - Empty Response
0x1a Unknown - Empty Response
0x1c Unknown - Empty Response
0x1d Unknown - Empty Response
0x1e Unknown - Empty Response
0x1f Unknown - Empty Response
0x20 Unknown - Empty Response
0x26 Various Operantion Mode Flags
0x27 Unknown
0x28 Various Operantion Mode Flags
0x29 Zone 1 & 2 Temperatures
0xa1 Consumed Energy
0xa2 Delivered Energy

Payload - All Commands

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Command 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Set Response - Packet Type 0x61

Available Commands

Active commands so far identified.

Command Brief Description
0x00 OK

0x00 - OK , Command OK, or Just Format?

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Command 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Get Response - Packet Type 0x62

Resposes

Responses so far identified.

Command Brief Description
0x01 Time & Date
0x05 Various Flags
0x09 Zone 1 & 2 Temperatures and Setpoints, Hot Water Setpoint
0x0b Zone 1 & 2 and Outside Temperature
0x0c Water Flow Temperatures
0x0d Boiler Flow Temperatures
0x26 Various Operantion Mode Flags
0x28 Various Operantion Mode Flags
0x29 Zone 1 & 2 Temperatures

0x01 - Time & Date

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x01 Y M D h m s
  • Y: Year
  • M: Month
  • D: Day
  • h: Hour
  • m: Minute
  • s: Second

0x02 - Defrost

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x02 R D HR?
  • R: Own Refrigerant Address
  • D: Defrost
  • HR: Residual Heat Removal?

0x03 - Refrigerant and Zone Running Information

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x03 RF F1 F2 F3 F4 M MF
  • RF: Refrigerant Flt Code
  • F1: Fault Code * 100 + Flt Code (F2) (Numbers)
  • F3: Fault Code (Letter) 1
  • F4: Fault Code (Letter) 2
  • M: Multi Zone Running Parameter (3 = Z2 Working, 2 = Z1 Working, 1 = Both Zones working, 0 = Idle)

0x04 - Various Flags

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x04 CF
  • CF : Compressor Frequency
  • Slave Frequency in other bytes

0x05 - Various Flags

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x05 DE HS HW
  • DE : Value of 7 given in various running modes
  • HS : Heat Source (Suspected) 0 = H/P, 1 = IH, 2 = BH, 3 = IH + BH, 4 = Boiler
  • HW : Hot Water Running Mode (0 = Off, 1 = Heat Pump Phase, 2 = Heater Phase (e.g. Immersion or Booster))

0x07 - Heater Power

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x07 I P
  • I : Input Power (kW) - 0 = 0-1kW, 1 = 1-2kW, 2 = 2-3kW etc.
  • P : Heater Power (to nearest kW)

0x09 - Zone 1 & 2 Temperatures and Setpoints, Hot Water Setpoint

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x09 Z1T Z1T Z2T Z2T Z1ST Z1SP Z2SP Z2SP LSP LSP HWD FMx FMn
  • Z1T : Zone1 Target Temperature * 100
  • Z2T : Zone2 Target Temperature * 100;
  • Z1SP : Zone 1 Flow SetFlow Setpoint * 100
  • Z2SP : Zone 2 Flow SetFlow Setpoint * 100
  • LSP : Legionella Setpoint * 100
  • HWD : DHW Max Temp Drop -40 / 2
  • FMx : Flow Maximum Temperature -40 / 2
  • FMn : Flow Minimum Temperature -40 / 2

0x0b - Zone 1 & 2 and Outside Temperature

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x0b Z1T Z1T Z2T Z2T ? ? RT RT CT O
  • Z1T : Zone1 Temperature * 100
  • Z2T : Zone2 Temperature * 100
  • RT : Refrigerant Temperature * 100 (Where TH2 is installed)
  • CT : Condensing Temperature /2 - 40
  • O : Outside Temp /2 - 40

0x0c - Heater Flow Temps

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x0c OF OF RF RF HW HW HW2 HW2
  • OF : Heater Water Out Flow * 100
  • RF : Heater Return Flow Temperature * 100
  • HW : Hot Water Temperature * 100 (THW5 or THW5B)
  • HW2 : Hot Water Temperature * 100 (THW5A if installed)

0x0d - Thermistors 1

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x0d F1 F1 R1 R1 F2 F2 R2 R2
  • F1 : Zone 1 Flow Temperature * 100 (Where THW6 installed)
  • R1 : Zone 1 Return Temperature * 100 (Where THW7 is installed)
  • F2 : Zone 2 Flow Temperature * 100 (Where THW8 installed)
  • R2 : Zone 2 Return Temperature * 100 (Where THW9 is installed)

0x0e - Thermistors 2

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x0e F F R R
  • F : Boiler Flow Temperature * 100 (Where THWB1 installed)
  • R : Boiler Return Temperature * 100 (Where THWB2 is installed)

0x0f - Thermistors 3 (FTC6+ Only)

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x0f M M C C
  • M : Mixing Tank Temperature * 100 (Where THW10 is installed)
  • C : Condensing Temperature * 100

0x10 - Hardwired Thermostats

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x10 Z1T Z2T OT
  • Z1T: Hardwired/External (IN1) Thermostat 1 Demand (On/Off)
  • Z2T: Hardwired/External (IN6) Thermostat 2 Demand (On/Off)
  • OT: Hardwired/External (IN5) Outdoor Thermostat Demand (On/Off)

0x11 - Dip Switches?

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x10 1 3 4 5 6
  • Switch 1
  • Switch 3
  • Switch 4
  • Switch 5
  • Switch 6

0x13 - Run Hours

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x13 U RH RH RH
  • U : Unknown
  • RH: Run Hours

0x14 - Immerson/Booster and Primary Flow Rate

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x14 B I PF
  • B : Booster Heater Active
  • I : Immersion Heater Active
  • PF : Primary Flow Rate (l/min)

0x15 - Unknown

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x15 PP U2 U2 P2 TWV TWV2 U5
  • PP : Primary Water Pump (Pump 1/OUT1)
  • U2 : Unknown Int (3+4 Two Bytes?)
  • P2 : Water Pump 2 (OUT2)
  • TWV : Three Way Valve Active
  • TWV2 : Three Way Valve 2 Active (Suspected, if installed)
  • U5 : Unknown - Always shows 04?

0x16 - Pumps Running

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x16 O4 O3 O13
  • O4 : Pump 4 (CPN4)
  • O13 : Pump Output (Out13)
  • O3 : Pump Output (Out3)

0x26 - Operation Information

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x26 Pwr OM HW OpZ1 OpZ2 HWSP HWSP HSP HSP SP SP ??
  • Pwr - Power
    • 0 : Standby
    • 1 : On
  • OM Operation Mode
    • 0 : Off
    • 1 : Hot Water On
    • 2 : Heating On
    • 5 : Frost Protect
    • 6 : Legionella
  • HW - Hot Water Mode
    • 0 : Normal
    • 1 : Economy
  • Op - Operation Mode (Zone 1 / Zone 2):
    • 0 : Heating Temperature Mode
    • 1 : Heating Flow Control Mode
    • 2 : Heating Compensation Curve Mode
    • 3 : Cooling Temperature Mode
    • 4 : Cooling Flow Control Mode
    • 5 : Dry Up
  • HWSP : HotWater SetPoint * 100;
  • HSP : Heating Flow SetPoint * 100;
  • SP : External Flow SetPoint
  • ?? : 1 for a few cycles when writing to 0x32 byte 14

0x28 - Various Flags

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x28 FHW HM HT PHZ1 PCZ1 PHZ2 PCZ2 SC
  • FHW : Forced DHW Mode Active
  • HM : Holiday Mode
  • HT : Prohibit DHW
  • PHZ1 : Prohibit Heating Zone1
  • PCZ1 : Prohibit Cooling Zone1
  • PHZ2 : Prohibit Heating Zone2
  • PCZ2 : Prohibit Cooling Zone2
  • SC : Server Control Mode Active

0x29 - Thermostats

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0x29 HC Z1T Z1T Z2T Z2T
  • HC : Heating (0) / Cooling (1)
  • Z1T : Zone1 Temperature * 100
  • Z2T : Zone2 Temperature * 100

0xA1 - Consumed Energy

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0xA1 Y M D Heat Cool DHW
  • Y: Year
  • M: Month
  • D: Day

0xA2 - Delivered Energy

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0xA2 Y M D Heat Cool DHW
  • Y: Year
  • M: Month
  • D: Day

0xC9 - FTC Information

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0xC9 U1 U2 U3 V
  • U1: Version of Protocol (Upper/Lower) BCD
  • U2: Version of Model (Upper/Lower) BCD
  • U3: Capacity of Supply
  • V: FTC Version: 0: FTC2B 1: FTC4 2: FTC5 3: FTC6 5: FTC7 128: CAHV1A 129: CAHV1B 130: CRHV1A 131: CRHV1B 132: EAHV1A 133: EAHV1B 134: QAHV1A 135: QAHV1B 144: PWFY1