Notifications
You must be signed in to change notification settings - Fork 34
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Unhandled data received #67
Comments
Could you provide some more log messages? |
Could you provide your configuration YAML too? |
|
` 21:21:03 | [W] | [seplos_bms:022] | Unhandled data received (data_len: 0x40): 20.03.46.5A.C0.40.00.01.0C.F9.0C.ED.0B.A0.0B.94.FD.EE.14.B8.67.96.6D.60.03.B3.14.BA.00.00.00.00.00.00.03.02.80.41 (38) |
I use this setting: logger: level: DEBUG Can I create a more detailed logfile? |
Today I activated "Auto Address Coding" in the BMS Settings. The result gave me a big headache, but during debuging I recognized that "Unhandled data received" messages disappeared in the esp . After deactivation of this feature the messages came back. Maybe this is a hint to the root cause for this messages |
any news on this topic- i do have a similar problem. |
I have an esp32 connected to the Master BMS of a set 4 batteries with Seplos 10E 200A with BT. The connectivity to the BMS is not very stable and I recieve errors every second in the log. The registers of the 3 slaves are not updated every interval. Sometimes it updates just the registers of one or two packs.
RS485 is powered by 5V. Same behavior with 3.3V. Do youhave any idea what causes this behavior?
The text was updated successfully, but these errors were encountered: