Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Voltronic Axpert IV Twin 6K new esp8266-example.yaml #151

Open
Alarico77 opened this issue Sep 30, 2024 · 11 comments
Open

Voltronic Axpert IV Twin 6K new esp8266-example.yaml #151

Alarico77 opened this issue Sep 30, 2024 · 11 comments

Comments

@Alarico77
Copy link

Hi, I'm trying to install the new esp8266-example.yaml, with the old syssi.esphome-pipsolar@main I read the inverter data (not all, but it's ok). When I install the .yaml file, it gives me some timeout errors, and in the dashboard all the sensors are unknown. I attach a log:

@Alarico77 Alarico77 changed the title Voltronic Axper IV Twin 6K new esp8266-example.yaml Voltronic Axpert IV Twin 6K new esp8266-example.yaml Sep 30, 2024
@syssi
Copy link
Owner

syssi commented Sep 30, 2024

Could you provide the log with debug output of the uart component enabled (see https://github.com/syssi/esphome-pipsolar?tab=readme-ov-file#debugging)? I would like to see the raw traffic of your inverter.

@Alarico77
Copy link
Author

can't you see it????

logs_voltronic-axpert_run (4).txt

@Alarico77
Copy link
Author

Alarico77 commented Sep 30, 2024

Now I see it... I see it

I'm really happy thank you, thank you.

@Alarico77
Copy link
Author

image

@syssi
Copy link
Owner

syssi commented Oct 1, 2024

This looks good to me. What do you miss?

@syssi
Copy link
Owner

syssi commented Oct 1, 2024

It looks like your inverter doesn't support the QPIGS2 and QBATCD command. Do you miss measurements of the second PV string?

@Alarico77
Copy link
Author

I have charge regulators, so I have not connected PV strings to the inverter.
Instead, the commands to send to the inverter, you are right, they do not work. I tried to set "Current_max_ac_charging_current_select" from 20A to 10A, but it always remains at 20.

@syssi
Copy link
Owner

syssi commented Oct 1, 2024

For successful commands the inverter responds with ACKnowledge. If a command isn't accepted the response is NAK (not acknowledged).

@Alarico77
Copy link
Author

OK some do, some don't.
it's a bit unstable, in the sense that the connection drops often.

@syssi
Copy link
Owner

syssi commented Oct 1, 2024

I cannot help here if you don't explain in detail what you are looking for.

@Alarico77
Copy link
Author

Alarico77 commented Oct 1, 2024

I'd better check my wifi network first. ;-)
everything seems OK thanks.
I will come back to ask questions to learn better from you. thank you

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

2 participants