Measure 12V rail crosstalk and resistance.
- Connect the DMM to the J3 connector on the first slot
- Connect the DMM to the J3 connector on the second slot
- Enable heaters on card 1; run them at two power levels (2A and higher)
- Measure voltage for both power levels and without heaters on both cards
- Repeat steps 1-4 for the next slots, 2-3, 3-4, 4-5, 5-6, 6-7, 7-8, 1-4, 1-8, 4-8
- Calculate the voltage drop for both cases, calculate internal rail resistance for each slot and crosstalk value