Overload warning for load cell channels #73

Open
petebachant opened this issue Mar 17, 2024 · 2 comments
Open

Overload warning for load cell channels #73

petebachant opened this issue Mar 17, 2024 · 2 comments

Comments

@petebachant
Copy link
Owner

Notify tank operator if load cells are recording values close to their upper limit

@petebachant petebachant converted this from a draft issue Mar 17, 2024
@petebachant
Copy link
Owner Author

From @meganandd

@Pamboukes
Copy link
Collaborator

Pamboukes commented Mar 22, 2024

Safe overload = 150% of full scale capacity for each channel. I would recomend warnings at 100% and 125% of full scale.

FS Capacity of each channel:

Mx = 47 N-m
My = 172 N-m
Fz = 1885 N
Mz = 222 N-m

Should we use this to cause the system to shut down if overload reaches some threshold? These moments/forces are caused by the turbine running, in practice, so automating to stop the rotor and stop the carriage if said threshold is met may be a good idea? Could include an ovverride switch if that was helpful for some reason.

@meganandd meganandd moved this from Backlog to Ready in TurbineDAQ AFT compatibility Mar 22, 2024