Error:CMD:cmd SENSOR NOT found in logs #1391
Comments
This error comes when you enable I have tried increasing the TeleInterval:
|
I see, I've pushed a fix to silence it, can you check now? |
Flashed Built on Oct 20 2024 14:44:11 version 1.17.754 The error for SENSOR is suppressed now.
However the error for RESULT still appeared:
|
I see, thanks, I've added Result stub now, can you check? |
Flashed 1.17.755 and now the error is gone.
Thanks a lot for the quick fixes! |
Describe the bug
Error:CMD:cmd SENSOR NOT found in logs.
Firmware:
I have following flags enabled:
Flag 2 - [MQTT] Broadcast self state every N (def: 60) seconds (delay configurable by 'mqtt_broadcastInterval' and 'mqtt_broadcastItemsPerSec' commands)
Flag 10 - [MQTT] Broadcast self state on MQTT connect
Flag 21 - [MQTT] Retain power channels (Relay channels, etc)
Flag 30 - [MQTT] Enable Tasmota TELE etc publishes (for ioBroker etc)
Drivers are running:
3 drivers active (Charts,NTP,BL0937), total 37
autoexec.bat
To Reproduce
Additional context
I had the plugs on 1.17.243 but unused for a while. I could not recall seeing this message in the log. After the upgrade I noticed the error.
Also after bootup similar error is seen for RESULT:
The text was updated successfully, but these errors were encountered: