Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathsensorless.cfg
45 lines (40 loc) · 1.63 KB
/
sensorless.cfg
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
[gcode_macro _HOME_X]
gcode:
# Always use consistent run_current on A/B steppers during sensorless homing
{% set RUN_CURRENT_X = printer.configfile.settings['tmc2240 stepper_x'].run_current|float %}
{% set RUN_CURRENT_Y = printer.configfile.settings['tmc2240 stepper_y'].run_current|float %}
{% set HOME_CURRENT = 0.6 %}
#SET_TMC_FIELD FIELD=SGTHRS STEPPER=stepper_x VALUE=90
SET_TMC_CURRENT STEPPER=stepper_x CURRENT={HOME_CURRENT}
SET_TMC_CURRENT STEPPER=stepper_y CURRENT={HOME_CURRENT}
# Home
G28 X
# Move away
G91
G1 X-10 F1200
G90
# Wait just a second… (give StallGuard registers time to clear)
G4 P1000
# Set current during print
SET_TMC_CURRENT STEPPER=stepper_x CURRENT={RUN_CURRENT_X}
SET_TMC_CURRENT STEPPER=stepper_y CURRENT={RUN_CURRENT_Y}
[gcode_macro _HOME_Y]
gcode:
# Set current for sensorless homing
{% set RUN_CURRENT_X = printer.configfile.settings['tmc2240 stepper_x'].run_current|float %}
{% set RUN_CURRENT_Y = printer.configfile.settings['tmc2240 stepper_y'].run_current|float %}
{% set HOME_CURRENT = 0.6 %}
#SET_TMC_FIELD FIELD=SGTHRS STEPPER=stepper_y VALUE=90
SET_TMC_CURRENT STEPPER=stepper_x CURRENT={HOME_CURRENT}
SET_TMC_CURRENT STEPPER=stepper_y CURRENT={HOME_CURRENT}
# Home
G28 Y
# Move away
G91
G1 Y-10 F1200
G90
# Wait just a second… (give StallGuard registers time to clear)
G4 P1000
# Set current during print
SET_TMC_CURRENT STEPPER=stepper_x CURRENT={RUN_CURRENT_X}
SET_TMC_CURRENT STEPPER=stepper_y CURRENT={RUN_CURRENT_Y}