When one commutation is finished,the timer2 counter is set with Wt_ZC_Tout_Start, in order to know whether zero cross check is timeout.
But when a new zero cross point checking start,Flag_Demag_Detected is set.
And if there is a wrong comparator output, in the function comp_read_wrong_extend_timeout,the timeout check counter timer2 is reset as followed:
comp_read_wrong:
jb Flag_Startup_Phase, comp_read_wrong_startup
jb Flag_Demag_Detected, comp_read_wrong_extend_timeout
inc Temp3 ; Increment number of OK readings required
clr C
mov A, Temp3
subb A, Temp4
jc comp_check_timeout ; If below initial requirement - take another reading
sjmp comp_start ; Otherwise - go back and restart
comp_read_wrong_startup:
inc Temp3 ; Increment number of OK readings required
clr C
mov A, Temp3
subb A, Temp4 ; If above initial requirement - do not increment further
jc ($+3)
dec Temp3
sjmp comp_check_timeout ; Continue to look for good ones
comp_read_wrong_extend_timeout:
clr Flag_Demag_Detected ; Clear demag detected flag
anl EIE1, #7Fh ; Disable Timer3 interrupts
mov TMR3CN0, #00h ; Timer3 disabled and interrupt flag cleared
jnb Flag_High_Rpm, comp_read_wrong_low_rpm ; Branch if not high rpm
mov TMR3L, #0 ; Set timeout to ~1ms
mov TMR3H, #-(8 SHL MCU_48MHZ)
As above description, if a wrong comparator out is got when Flag_Demag_Detected is set,the timeout check time must be reset.So whether the timeout check time of Wt_ZC_Tout_Start is not need,it's can be directly set as the value of what comp_read_wrong_extend_timeout set.
Bluejay version
0.16
ESC variant
ah5
PWM frequency
24
DShot bitrate
150
Bidirectional DShot
Off
FC firmware
4.2.9
Motor size
0802
Configurator debug log
no
The text was updated successfully, but these errors were encountered:
Describe the issue
When one commutation is finished,the timer2 counter is set with Wt_ZC_Tout_Start, in order to know whether zero cross check is timeout.
But when a new zero cross point checking start,Flag_Demag_Detected is set.
And if there is a wrong comparator output, in the function comp_read_wrong_extend_timeout,the timeout check counter timer2 is reset as followed:
As above description, if a wrong comparator out is got when Flag_Demag_Detected is set,the timeout check time must be reset.So whether the timeout check time of Wt_ZC_Tout_Start is not need,it's can be directly set as the value of what comp_read_wrong_extend_timeout set.