Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathconfig.yaml
186 lines (165 loc) · 5.56 KB
/
config.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
esphome:
name: test-can
friendly_name: test can
esp8266:
board: esp01_1m
# Enable logging
logger:
level: DEBUG
logs:
canbus: ERROR
# Enable Home Assistant API
api:
encryption:
key:
ota:
password:
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
manual_ip:
static_ip: 192.168.0.9
gateway: 192.168.0.1
subnet: 255.255.255.0
# Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: "Test-Can Fallback Hotspot"
password: "yZXII3swcU1w"
captive_portal:
spi:
id: McpSpi
clk_pin: GPIO16
mosi_pin: GPIO5
miso_pin: GPIO4
globals:
- id: dids
type: std::vector<std::vector<std::string>>
initial_value: '{
{"327", "OutdoorAirTemperatureSensor", {0x03, 0x22, 0x01, 0x47, 0x00, 0x00, 0x00, 0x00}},
{"328", "SupplyAirTemperatureSensor", {0x03, 0x22, 0x01, 0x48, 0x00, 0x00, 0x00, 0x00}},
{"329", "ExtractAirTemperatureSensor", {0x03, 0x22, 0x01, 0x49, 0x00, 0x00, 0x00, 0x00}},
{"330", "ExhaustAirTemperatureSensor", {0x03, 0x22, 0x01, 0x4A, 0x00, 0x00, 0x00, 0x00}},
{"419", "OutdoorAirHumiditySensor", {0x03, 0x22, 0x01, 0xA3, 0x00, 0x00, 0x00, 0x00}},
{"420", "SupplyAirHumiditySensor", {0x03, 0x22, 0x01, 0xA4, 0x00, 0x00, 0x00, 0x00}},
{"421", "ExtractAirHumiditySensor", {0x03, 0x22, 0x01, 0xA5, 0x00, 0x00, 0x00, 0x00}},
{"422", "ExhaustAirHumiditySensor", {0x03, 0x22, 0x01, 0xA6, 0x00, 0x00, 0x00, 0x00}},
}'
- id: loop_dids
type: int
restore_value: no
initial_value: '0'
canbus:
- platform: mcp2515
id: cb
spi_id: McpSpi
cs_pin: GPIO14
can_id: 680
bit_rate: 250kbps
on_frame:
- can_id: 0x690
then:
- lambda: |-
ESP_LOGD("deb", "empfangen: 0x%02X %02X %02X %02X %02X %02X %02X %02X", x[0], x[1], x[2], x[3], x[4], x[5], x[6], x[7]);
if(x[0]==0x10 and x[2]==0x62) {
if(x[1]==0x0C) {
int did = int16_t((x[4])+((x[3])<<8));
switch(did) {
case 327:
id(va327).publish_state(float(int16_t((x[5])+((x[6])<<8)))*0.1);
break;
case 328:
id(va328).publish_state(float(int16_t((x[5])+((x[6])<<8)))*0.1);
break;
case 329:
id(va329).publish_state(float(int16_t((x[5])+((x[6])<<8)))*0.1);
break;
case 330:
id(va330).publish_state(float(int16_t((x[5])+((x[6])<<8)))*0.1);
break;
}
}
if(x[1]==0x08) {
int did = int16_t((x[4])+((x[3])<<8));
switch(did) {
case 419:
id(va419).publish_state(int16_t(x[5]));
break;
case 420:
id(va420).publish_state(int16_t(x[5]));
break;
case 421:
id(va421).publish_state(int16_t(x[5]));
break;
case 422:
id(va422).publish_state(int16_t(x[5]));
break;
}
}
}
interval:
- interval: 2s
then:
- lambda: |-
int i = id(loop_dids);
std::vector< uint8_t > data0{ id(dids)[i][2][0], id(dids)[i][2][1], id(dids)[i][2][2], id(dids)[i][2][3], id(dids)[i][2][4], id(dids)[i][2][5], id(dids)[i][2][6], id(dids)[i][2][7] };
id(cb)->send_data(0x680, 0, data0);
ESP_LOGD("deb", "gesendet: 0x%02X %02X %02X %02X %02X %02X %02X %02X", id(dids)[i][2][0], id(dids)[i][2][1], id(dids)[i][2][2], id(dids)[i][2][3], id(dids)[i][2][4], id(dids)[i][2][5], id(dids)[i][2][6], id(dids)[i][2][7]);
if ( i < size(id(dids))-1) { id(loop_dids) = i + 1;}
else { id(loop_dids) = 0; }
sensor:
- platform: template
name: "Outdoor Air Temperature Sensor"
id: va327
unit_of_measurement: °C
device_class: temperature
state_class: "measurement"
accuracy_decimals: 1
- platform: template
name: "Supply Air Temperature Sensor"
id: va328
unit_of_measurement: °C
device_class: temperature
state_class: "measurement"
accuracy_decimals: 1
- platform: template
name: "Extract Air Temperature Sensor"
id: va329
unit_of_measurement: °C
device_class: temperature
state_class: "measurement"
accuracy_decimals: 1
- platform: template
name: "Exhaust Air Temperature Sensor"
id: va330
unit_of_measurement: °C
device_class: temperature
state_class: "measurement"
accuracy_decimals: 1
- platform: template
name: "Outdoor Air Humidity Sensor"
id: va419
unit_of_measurement: "%"
device_class: humidity
state_class: "measurement"
accuracy_decimals: 0
- platform: template
name: "Supply Air Humidity Sensor"
id: va420
unit_of_measurement: "%"
device_class: humidity
state_class: "measurement"
accuracy_decimals: 0
- platform: template
name: "Extract Air Humidity Sensor"
id: va421
unit_of_measurement: "%"
device_class: humidity
state_class: "measurement"
accuracy_decimals: 0
- platform: template
name: "Exhaust Air Humidity Sensor"
id: va422
unit_of_measurement: "%"
device_class: humidity
state_class: "measurement"
accuracy_decimals: 0