forked from stephentoub/coreclr
-
Notifications
You must be signed in to change notification settings - Fork 0
/
run.cmd
63 lines (54 loc) · 2.42 KB
/
run.cmd
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
@if not defined _echo @echo off
setlocal
:: Default to highest Visual Studio version available
::
:: For VS2015 (and prior), only a single instance is allowed to be installed on a box
:: and VS140COMNTOOLS is set as a global environment variable by the installer. This
:: allows users to locate where the instance of VS2015 is installed.
::
:: For VS2017, multiple instances can be installed on the same box SxS and VS150COMNTOOLS
:: is no longer set as a global environment variable and is instead only set if the user
:: has launched the VS2017 Developer Command Prompt.
::
:: Following this logic, we will default to the VS2017 toolset if VS150COMNTOOLS tools is
:: set, as this indicates the user is running from the VS2017 Developer Command Prompt and
:: is already configured to use that toolset. Otherwise, we will fallback to using the VS2015
:: toolset if it is installed. Finally, we will fail the script if no supported VS instance
:: can be found.
if defined VisualStudioVersion (
if not defined __VSVersion echo %__MsgPrefix%Detected Visual Studio %VisualStudioVersion% developer command ^prompt environment
goto :Run
)
set _VSWHERE="%ProgramFiles(x86)%\Microsoft Visual Studio\Installer\vswhere.exe"
if exist %_VSWHERE% (
for /f "usebackq tokens=*" %%i in (`%_VSWHERE% -latest -prerelease -property installationPath`) do set _VSCOMNTOOLS=%%i\Common7\Tools
)
if not exist "%_VSCOMNTOOLS%" set _VSCOMNTOOLS=%VS140COMNTOOLS%
if not exist "%_VSCOMNTOOLS%" (
echo %__MsgPrefix%Error: Visual Studio 2015 or 2017 required.
echo Please see https://github.com/dotnet/corefx/blob/master/Documentation/project-docs/developer-guide.md for build instructions.
exit /b 1
)
call "%_VSCOMNTOOLS%\VsDevCmd.bat"
:Run
:: Clear the 'Platform' env variable for this session, as it's a per-project setting within the build, and
:: misleading value (such as 'MCD' in HP PCs) may lead to build breakage (issue: #69).
set Platform=
:: Restore the Tools directory
call %~dp0init-tools.cmd
if NOT [%ERRORLEVEL%]==[0] (
exit /b 1
)
set _toolRuntime=%~dp0Tools
set _dotnet=%_toolRuntime%\dotnetcli\dotnet.exe
set _json=%~dp0config.json
:: run.exe depends on running in the root directory, notably because the config.json specifies
:: a relative path to the binclash logger
pushd %~dp0
echo Running: %_dotnet% %_toolRuntime%\run.exe %~dp0config.json %*
call %_dotnet% %_toolRuntime%\run.exe "%_json%" %*
popd
if NOT [%ERRORLEVEL%]==[0] (
exit /b 1
)
exit /b 0