26 changes: 25 additions & 1 deletion Changelog.md
Original file line number Diff line number Diff line change
@@ -1,3 +1,27 @@
## [16.0.0-RC5] - 2024-10-xx

For a full list of changes see [Full list of changes](https://github.com/jomjol/AI-on-the-edge-device/compare/v15.7.0...v16.0.0-RC1)

#### Known issues
Please check the [issues](https://github.com/jomjol/AI-on-the-edge-device/issues) and
[discussions](https://github.com/jomjol/AI-on-the-edge-device/discussions) before reporting a new issue.

#### Core Changes
Only changes since RC4 are listed:
- Updated the Homeassistant Discovery topics (#3332):
- `raw` has now set the `State Class` to `measurement`. Before it was always set to `""`.
- `value` has now only set the `State Class` to `total_increasing` if the parameter `Allow Negative Rates` is **not** set. Else it uses `measurement` since the rate could also be negative. Before it was always set to `total_increasing`.
- The `rate_per_time_unit` topic of an **Energy** meter needs a `Device Class`=`power`. For `gas` and `water` it should be `volume_flow_rate`. Before it was always set to `""`.

**:warning: Please check your Homeassistant instance to make sure it is handled correctly!**

#### Bug Fixes
Only changes since RC3 are listed:
- None




## [16.0.0-RC4] - 2024-10-06

For a full list of changes see [Full list of changes](https://github.com/jomjol/AI-on-the-edge-device/compare/v15.7.0...v16.0.0-RC1)
Expand All @@ -7,7 +31,7 @@ Please check the [issues](https://github.com/jomjol/AI-on-the-edge-device/issues
[discussions](https://github.com/jomjol/AI-on-the-edge-device/discussions) before reporting a new issue.

#### Core Changes
Only changes since RC2 are listed:
Only changes since RC3 are listed:
- Update esp32-camera submodule to `v2.0.13` (#3316)
- Added contributor list (#3317)
- Added files for demo mode (#3315)
Expand Down
4 changes: 2 additions & 2 deletions code/components/jomjol_flowcontroll/ClassFlowMQTT.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -151,7 +151,7 @@ bool ClassFlowMQTT::ReadParameter(FILE* pfile, string& aktparamgraph)
mqttServer_setMeterType("water", "L", "h", "L/h");
}
else if (toUpper(splitted[1]) == "WATER_FT3") {
mqttServer_setMeterType("water", "ft³", "m", "ft³/m"); // Minutes
mqttServer_setMeterType("water", "ft³", "m", "ft³/m"); // m = Minutes
}
else if (toUpper(splitted[1]) == "WATER_GAL") {
mqttServer_setMeterType("water", "gal", "h", "gal/h");
Expand All @@ -160,7 +160,7 @@ bool ClassFlowMQTT::ReadParameter(FILE* pfile, string& aktparamgraph)
mqttServer_setMeterType("gas", "", "h", "m³/h");
}
else if (toUpper(splitted[1]) == "GAS_FT3") {
mqttServer_setMeterType("gas", "ft³", "m", "ft³/m"); // Minutes
mqttServer_setMeterType("gas", "ft³", "m", "ft³/m"); // m = Minutes
}
else if (toUpper(splitted[1]) == "ENERGY_WH") {
mqttServer_setMeterType("energy", "Wh", "h", "W");
Expand Down
18 changes: 15 additions & 3 deletions code/components/jomjol_mqtt/server_mqtt.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -184,13 +184,25 @@ bool MQTThomeassistantDiscovery(int qos) {
group = "";
}

/* If "Allow neg. rate" is true, use "measurement" instead of "total_increasing" for the State Class, see https://github.com/jomjol/AI-on-the-edge-device/issues/3331 */
std::string value_state_class = "total_increasing";
if ((*NUMBERS)[i]->AllowNegativeRates) {
value_state_class = "measurement";
}

/* Energy meters need a different Device Class, see https://github.com/jomjol/AI-on-the-edge-device/issues/3333 */
std::string rate_device_class = "volume_flow_rate";
if (meterType == "energy") {
rate_device_class = "power";
}

// Group | Field | User Friendly Name | Icon | Unit | Device Class | State Class | Entity Category
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "value", "Value", "gauge", valueUnit, meterType, "total_increasing", "", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "raw", "Raw Value", "raw", "", "", "", "diagnostic", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "value", "Value", "gauge", valueUnit, meterType, value_state_class, "", qos); // State Class = "total_increasing" if <NUMBERS>.AllowNegativeRates = false, else use "measurement"
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "raw", "Raw Value", "raw", valueUnit, meterType, "measurement", "diagnostic", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "error", "Error", "alert-circle-outline", "", "", "", "diagnostic", qos);
/* Not announcing "rate" as it is better to use rate_per_time_unit resp. rate_per_digitization_round */
// allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "rate", "Rate (Unit/Minute)", "swap-vertical", "", "", "", ""); // Legacy, always Unit per Minute
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "rate_per_time_unit", "Rate (" + rateUnit + ")", "swap-vertical", rateUnit, "", "measurement", "", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "rate_per_time_unit", "Rate (" + rateUnit + ")", "swap-vertical", rateUnit, rate_device_class, "measurement", "", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "rate_per_digitization_round", "Change since last Digitization round", "arrow-expand-vertical", valueUnit, "", "measurement", "", qos); // correctly the Unit is Unit/Interval!
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "timestamp", "Timestamp", "clock-time-eight-outline", "", "timestamp", "", "diagnostic", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "json", "JSON", "code-json", "", "", "", "diagnostic", qos);
Expand Down

0 comments on commit c448ece