diff --git a/docs/endpoints/api-v1-data.mdx b/docs/endpoints/api-v1-data.mdx index 91b0822..7ca5c45 100644 --- a/docs/endpoints/api-v1-data.mdx +++ b/docs/endpoints/api-v1-data.mdx @@ -169,22 +169,22 @@ Content-Length: ### Data points -| Data | Type | Available for | Description | -| ------------------------- | ------ | ------------- | --------------------------------------------------------------------------- | -| wifi_ssid | String | All | The Wi-Fi network that the meter is connected to | -| wifi_strength | Number | All | The strength of the Wi-Fi signal in % | -| total_power_import_kwh | Number | All | The energy usage meter reading in kWh | -| total_power_import_t1_kwh | Number | All | Same value as `total_power_import_t1_kwh`, kept for backwards compatibility | -| total_power_export_kwh | Number | All | The energy feed-in meter reading in kWh | -| total_power_export_t1_kwh | Number | All | Same value as `total_power_export_kwh`, kept for backwards compatibility | -| active_power_w | Number | All | The total active usage in watt | -| active_power_l1_w | Number | All | Same value as `active_power_w`, kept for backwards compatibility | -| active_voltage_v | Number | All | The active voltage in volts | -| active_current_a | Number | All | The active current in amperes | -| active_reactive_power_var | Number | HWE-SKT-21 | The reactive power in volt-amperes reactive | -| active_apparent_power_va | Number | HWE-SKT-21 | The apparent power in volt-amperes | -| active_power_factor | Number | HWE-SKT-21 | The power factor | -| active_frequency_hz | Number | All | The frequency in hertz | +| Data | Type | Available for | Description | +| ------------------------- | ------ | ------------- | ------------------------------------------------------------------------ | +| wifi_ssid | String | All | The Wi-Fi network that the meter is connected to | +| wifi_strength | Number | All | The strength of the Wi-Fi signal in % | +| total_power_import_kwh | Number | All | The energy usage meter reading in kWh | +| total_power_import_t1_kwh | Number | All | Same value as `total_power_import_kwh`, kept for backwards compatibility | +| total_power_export_kwh | Number | All | The energy feed-in meter reading in kWh | +| total_power_export_t1_kwh | Number | All | Same value as `total_power_export_kwh`, kept for backwards compatibility | +| active_power_w | Number | All | The total active usage in watt | +| active_power_l1_w | Number | All | Same value as `active_power_w`, kept for backwards compatibility | +| active_voltage_v | Number | All | The active voltage in volts | +| active_current_a | Number | All | The active current in amperes | +| active_reactive_power_var | Number | HWE-SKT-21 | The reactive power in volt-amperes reactive | +| active_apparent_power_va | Number | HWE-SKT-21 | The apparent power in volt-amperes | +| active_power_factor | Number | HWE-SKT-21 | The power factor | +| active_frequency_hz | Number | All | The frequency in hertz | ### Example: HWE-SKT-11