Nikon D7000 raw white level too high #359
Comments
For the reference: this is where white point is specified in RawSpeed: Line 5309 in 8c9b377
|
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
The following shows a small part of an overexposed Nikon D7000 raw file in darktable 3.9.0+1483~gfb7ae22e9, with -1 EV applied in the exposure module, and raw clipping indicator enabled:
As you can see, most the magenta area is not marked as overexposed.
RawTherapee's camconst.json lists the max RGB levels as
"white": [ 16300, 15700, 16300 ], // typical R 16383, G 15778, B 16383
https://github.com/Beep6581/RawTherapee/blob/dev/rtengine/camconst.json#L1680
Changing the raw white level to 15780 (close to the 'typical' G level of 15778) produces the following - the clipping indicator closely matching the clipped (magenta) areas:
The text was updated successfully, but these errors were encountered: