forked from Anrijs/Aranet4-Python
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy patharanet.py
181 lines (143 loc) · 6.17 KB
/
aranet.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
import aranet4
import requests
import time
import datetime
import sys
import re
def readArg(argv, key, default, error="Invalid value"):
if key in argv:
idx = argv.index(key) + 1
if idx >= len(argv):
print(error)
raise Exception(error)
return argv[idx]
return default
def main(argv):
if len(argv) < 1:
print("Missing device address.")
return
if "help" in argv or "?" in argv:
print("Usage: python aranet.py DEVICE_ADDRESS [OPTIONS]")
print("Options:")
print(" -h Fetch history")
print(" -hs <date> History range start (UTC time, example: 2019-09-29T14:00:00Z)")
print(" -he <date> History range end (UTC time, example: 2019-09-30T14:00:00Z)")
print(" -o <file> Save history results to file")
print(" -w Do not wait for sync before pulling history")
print(" -l <count> Get <count> last records")
print(" -u <url> Remote url for current value push")
print(" -p <params> History values to pull (default = thpc)")
print(" t - Temperature")
print(" h - Humidity")
print(" p - Pressure")
print(" c - CO2")
print("")
return
wait = "-w" not in argv
history = "-h" in argv
output = readArg(argv, "-o", '', "Missing output file name")
limit = int(readArg(argv, "-l", 0, "Missing limit value"))
url = readArg(argv, "-u", '', "Invalid url")
params = readArg(argv, "-p", "thpc", "Missing params value")
histStartStr = readArg(argv, "-hs", '', "Missing history range start value")
histEndStr = readArg(argv, "-he", '', "Missing history range end value")
histStart = None
histEnd = None
if len(histStartStr) > 0 or len(histEndStr) > 0:
if len(histStartStr) > 0:
histStart = datetime.datetime.strptime(histStartStr, "%Y-%m-%dT%H:%M:%SZ")
else:
histStart = datetime.datetime(1970, 1, 1)
if len(histEndStr) > 0:
histEnd = datetime.datetime.strptime(histEndStr, "%Y-%m-%dT%H:%M:%SZ")
else:
histEnd = datetime.datetime.utcnow()
if limit != 0:
print("Limit parameter (-l) will be ignored, because -start and/or -end is already defined")
limit = 0
device_mac = argv[0]
ar4 = aranet4.Aranet4(device_mac)
name = ar4.getName()
ver = ar4.getVersion()
current = ar4.currentReadings(False)
interval = ar4.getInterval() #current["interval"]
ago = ar4.getSecondsSinceUpdate() #current["ago"]
readings = ar4.getTotalReadings()
print("--------------------------------------")
print("Connected: {:s} | {:s}".format(name,ver))
print("Updated {:d} s ago. Intervals: {:d} s".format(ago, interval))
print("{:d} total readings".format(readings))
print("--------------------------------------")
print("CO2: {:d} ppm".format(current["co2"]))
print("Temperature: {:.2f} C".format(current["temperature"]))
print("Humidity: {:d} %".format(current["humidity"]))
print("Pressure: {:.2f} hPa".format(current["pressure"]))
print("Battery: {:d} %".format(current["battery"]))
print("--------------------------------------")
if url != "":
# get current measurement minute
t = time.time() - ago
#t = t - t % 60 # epoch, floored to minutes
r = requests.post(url, data = {
'time':t,
'co2':current["co2"],
'temperature':current["temperature"],
'pressure':current["pressure"],
'humidity':current["humidity"],
'battery':current["battery"]
})
print("Pushing data: {:s}".format(r.text))
if history:
start = 0
end = readings
if limit != 0:
start = end - limit
readCount = end - start
if histStart and histEnd:
oldest = datetime.datetime.utcnow() - datetime.timedelta(seconds=readCount*interval)
if (oldest > histStart):
histStart = oldest
readCount = (histEnd - histStart).total_seconds() / interval
paramsMod = 1.0
if "t" not in params: paramsMod -= 0.25
if "h" not in params: paramsMod -= 0.25
if "p" not in params: paramsMod -= 0.25
if "c" not in params: paramsMod -= 0.25
# it takes about 8 seconds per parameter for 5040 record pull
requiredTime = ((readCount / 150) + 2) * paramsMod # with nextra padding
if (wait and ago > interval - requiredTime):
# It takes about 5 seconds to read history for each parameter. 504->501->490 idx:4084-85-86 13:18pre
# We will wait for next measurement to keep data arrays aligned
tsleep = (interval - ago) + 5
print("Waiting {:d} seconds for measurement".format(tsleep))
time.sleep(tsleep) # +5s padding
tim0 = time.time()
if histStart and histEnd:
print("Fetching {:d} points of sensor history in date range {:s} -> {:s}...".format(
int(readCount),
histStart.strftime("%Y-%m-%dT%H:%M:%SZ"),
histEnd.strftime("%Y-%m-%dT%H:%M:%SZ")))
results = ar4.pullTimedInRange(histStart, histEnd, params)
else:
print("Fetching {:d} points of sensor history...".format(int(readCount)))
results = ar4.pullTimedHistory(start, end, params)
print("Pulled {:d} records in {:f} seconds".format(len(results), (time.time()-tim0)))
f = False
if output != "":
f = open(output, "w")
for r in results:
strtim = datetime.datetime.utcfromtimestamp(r["time"]).strftime('%Y-%m-%d %H:%M:%S')
t = r["temperature"]
p = r["pressure"]
h = r["humidity"]
c = r["co2"]
i = r["id"]
csv = "{:d};{:s};{:2.2f};{:d};{:.1f};{:d}".format(i, strtim, t, h, p, c)
if (f):
f.write(csv)
f.write("\n")
else:
print(csv)
if (f): f.close()