diff --git a/HPXMLtoOpenStudio/measure.xml b/HPXMLtoOpenStudio/measure.xml
index 3bf6e92fc5..2d7f57822c 100644
--- a/HPXMLtoOpenStudio/measure.xml
+++ b/HPXMLtoOpenStudio/measure.xml
@@ -3,8 +3,8 @@
3.1
hpxm_lto_openstudio
b1543b30-9465-45ff-ba04-1d1f85e763bc
- e132edac-0dde-4fa7-870f-6467cff2caf5
- 2024-10-23T17:44:12Z
+ a34fa4e4-deee-4e59-8f0b-8c1a2c574cdc
+ 2024-10-23T18:46:26Z
D8922A73
HPXMLtoOpenStudio
HPXML to OpenStudio Translator
@@ -651,7 +651,7 @@
test_airflow.rb
rb
test
- D1425F08
+ D4E42045
test_battery.rb
diff --git a/HPXMLtoOpenStudio/tests/test_airflow.rb b/HPXMLtoOpenStudio/tests/test_airflow.rb
index a47a60b2bd..114a01234c 100644
--- a/HPXMLtoOpenStudio/tests/test_airflow.rb
+++ b/HPXMLtoOpenStudio/tests/test_airflow.rb
@@ -384,7 +384,7 @@ def test_mechanical_ventilation_cfis
assert_in_epsilon(vent_fan_cfm, UnitConversions.convert(program_values['Q_duct_oa'].sum, 'm^3/s', 'cfm'), 0.01)
assert_in_epsilon(0.0, UnitConversions.convert(program_values['QWHV_sup'].sum, 'm^3/s', 'cfm'), 0.01)
assert_in_epsilon(0.0, UnitConversions.convert(program_values['QWHV_exh'].sum, 'm^3/s', 'cfm'), 0.01)
- assert_in_epsilon(vent_fan_power, program_values['fan_w'].sum, 0.01)
+ assert_in_epsilon(vent_fan_power, program_values['ah_fan_w'].sum, 0.01)
assert_in_epsilon(vent_fan_mins, program_values['t_min_hr_open'].sum, 0.01)
assert_in_epsilon(0.0, UnitConversions.convert(program_values['Qrange'].sum, 'm^3/s', 'cfm'), 0.01)
assert_in_epsilon(0.0, UnitConversions.convert(program_values['Qbath'].sum, 'm^3/s', 'cfm'), 0.01)
@@ -516,7 +516,7 @@ def test_multiple_mechvent
assert_equal(1, get_eed_for_ventilation(model, Constants::ObjectTypeMechanicalVentilationHouseFan).size)
assert_in_epsilon(total_mechvent_pow, get_eed_for_ventilation(model, Constants::ObjectTypeMechanicalVentilationHouseFan)[0].designLevel.get, 0.01)
assert_in_epsilon(fraction_heat_lost, get_eed_for_ventilation(model, Constants::ObjectTypeMechanicalVentilationHouseFan)[0].fractionLost, 0.01)
- assert_in_epsilon(vent_fan_power_cfis, program_values['fan_w'].sum, 0.01)
+ assert_in_epsilon(vent_fan_power_cfis, program_values['ah_fan_w'].sum, 0.01)
range_fan_eeds = get_eed_for_ventilation(model, Constants::ObjectTypeMechanicalVentilationRangeFan)
assert_equal(2, range_fan_eeds.size)
assert_in_epsilon(kitchen_fan_power, range_fan_eeds.map { |f| f.designLevel.get }.sum(0.0), 0.01)
@@ -573,7 +573,7 @@ def test_shared_mechvent_multiple
program_values = get_ems_values(model.getEnergyManagementSystemPrograms, "#{Constants::ObjectTypeInfiltration} program")
assert_in_epsilon((vent_fans_cfm_oa_preheat_sup + vent_fans_cfm_oa_preheat_bal + vent_fans_cfm_oa_preheat_ervhrv), UnitConversions.convert(program_values['Qpreheat'].sum, 'm^3/s', 'cfm'), 0.01)
assert_in_epsilon((vent_fans_cfm_oa_precool_sup + vent_fans_cfm_oa_precool_bal + vent_fans_cfm_oa_precool_ervhrv), UnitConversions.convert(program_values['Qprecool'].sum, 'm^3/s', 'cfm'), 0.01)
- assert_in_epsilon(vent_fans_pow_cfis, program_values['fan_w'].sum, 0.01)
+ assert_in_epsilon(vent_fans_pow_cfis, program_values['ah_fan_w'].sum, 0.01)
assert_in_epsilon(vent_fans_mins_cfis, program_values['t_min_hr_open'].sum, 0.01)
assert_in_epsilon(vent_fans_cfm_oa_cfis, UnitConversions.convert(program_values['Q_duct_oa'].sum, 'm^3/s', 'cfm'), 0.01)
assert_in_epsilon(vent_fans_cfm_tot_sup + vent_fans_cfm_tot_ervhrvbal, UnitConversions.convert(program_values['QWHV_sup'].sum, 'm^3/s', 'cfm'), 0.01)