Notifications
You must be signed in to change notification settings - Fork 23
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Feedback: Battery Sense and Orion Smart DCDC is working #20
Comments
Similar results here with an OrionSmart DC-DC charger. If the charger is off, the output voltage is shown as Everything else, including data from my SmartSolar 75-15, is displayed as expected. Great Work! |
Should the component submit no value (like your filter), |
My filter is causing HA to keep the last value which may not be so good. |
Hi @HBK1, can you please test the changes? |
It is working ok with 0.0V , Thanks! There is a warning in the log, is this anything to be worried about?
|
The warning is because EspHome changed the log level of this message from verbose to warn. |
Victron Battery Sense reports as Battery Monitor and presents BATTERY_VOLTAGE and TEMPERATURE.
Orion Smart DCDC needs a filter on OUTPUT_VOLTAGE since it reports 0x7FFF=32767 when engine is off=Unavalible.
Both are working ok together with a Smartshunt and MPPT on the same ESP32.
See below config for DCDC and Battery Sense:
The text was updated successfully, but these errors were encountered: